HLV-1Z 数显自动转塔显微维氏硬度计
来源:
作者:中国无损检测 人气: 发布时间:2024-11-22
摘要:机器主要参数 1试验力的级数: 试验力共8级:本机器上采用kgf单位,见表2.1 表2.1 Kgf 0.01 0.025 0.05 0.1 0.2 0.3 0.5 1 N 0.098 0.245 0.49 0.98 1.96 2.94 4.90 9.80 所以维氏标尺为:HV0.01, HV0.025, HV0.05, HV0.1,HV0.2, HV0.3, HV0.5,HV1 2 硬度示值误
机器主要参数
1试验力的级数:
试验力共8级:本机器上采用kgf单位,见表2.1
表2.1
Kgf
|
0.01
|
0.025
|
0.05
|
0.1
|
0.2
|
0.3
|
0.5
|
1
|
N
|
0.098
|
0.245
|
0.49
|
0.98
|
1.96
|
2.94
|
4.90
|
9.80
|
所以 维氏标尺为:HV0.01, HV0.025, HV0.05, HV0.1,HV0.2, HV0.3, HV0.5,HV1
本机器硬度 测量范围:5-3000HV,精度满足或高于GB/T4340.2见表2.2
表2.2
硬
度
符
号
|
最大误差
|
硬度,HV
|
50
|
100
|
150
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
600
|
700
|
800
|
HV0.01 |
|
|
|
|
|
|
|
|
|
|
|
|
|
HV0.025 |
8
|
10
|
|
|
|
|
|
|
|
|
|
|
|
HV0.05 |
6
|
8
|
9
|
10
|
|
|
|
|
|
|
|
|
|
HV0.1 |
5
|
6
|
7
|
8
|
8
|
9
|
10
|
10
|
11
|
|
|
|
|
HV0.2 |
|
4
|
|
6
|
|
8
|
|
9
|
|
10
|
11
|
11
|
12
|
HV0.3 |
|
4
|
|
5
|
|
6
|
|
7
|
|
8
|
9
|
10
|
10
|
HV0.5 |
|
3
|
|
5
|
|
5
|
|
6
|
|
6
|
7
|
7
|
8
|
HV1 |
|
3
|
|
4
|
|
4
|
|
4
|
|
5
|
5
|
5
|
6
|
注:
|
1.当压痕对角线小于0.020mm时,表中不给出误差值。 |
2.对于中间值,其最大允许误差可由内插法求得。 |
3.表中值是以0.001mm或压痕对角线平均值的2%为最大误差给出的,以较大者为准。 |
表中内容摘于GB/T4340.2。
3.光学系统:见表2.3
表2.3
物镜
|
10×(观察)
|
40×(测量)
|
目镜
|
10×
|
总放大倍数
|
100×(观察)
|
400×(测量)
|
测量分辨率
|
|
0.03125μm
|
卤素灯亮度
|
20级可调
|
当机器超过30分钟没有任何操作时,卤素灯将关掉,按任意键可唤醒。
5. 试验力保荷时间: 5~60s(每1秒为一单位)
6. 试件最大高度: 90mm
7 压头中心到外壁距离: 120mm
8.主机重量: 约40Kg
9 电源: AC220V/50Hz
10.外型尺寸:(长×宽×高) (490×290×530)mm
11.XY平台
XY平台参数见表2.4
表2.4
尺寸
|
100×100mm
|
行程
|
25×25mm
|
分辨率
|
0.01mm
|
电磁测厚仪http://www.diancicehouyi.com 铸铁测厚仪http://www.zhutiecehouyi.com
腐蚀 检测仪http://www.fushijianceyi.com 超音波 测厚仪http://www.chaoyinbocehouyi.com
电磁超声测厚仪http://www.diancichaoshengcehouyi.com
|
责任编辑:中国无损检测 转载请注明出处 www.wusunjiance.net